Electrical contacts : (Record no. 71555)
[ view plain ]
000 -LEADER | |
---|---|
fixed length control field | 03024cam a2200373Ii 4500 |
001 - CONTROL NUMBER | |
control field | 9781315216829 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
fixed length control field | 180331t20142014fluad ob 001 0 eng d |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781315216829 |
-- | (e-book : PDF) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781351824026 |
-- | (e-book: Mobi) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
ISBN | 9781439881316 |
-- | (e-book: PDF) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
-- | (hardback) |
020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
-- | (paperback) |
082 04 - CLASSIFICATION NUMBER | |
Call Number | 621.31042 |
-- | E383 |
245 00 - TITLE STATEMENT | |
Title | Electrical contacts : |
Sub Title | principles and applications / |
250 ## - EDITION STATEMENT | |
Edition statement | Second edition. |
300 ## - PHYSICAL DESCRIPTION | |
Number of Pages | 1 online resource |
505 0# - FORMATTED CONTENTS NOTE | |
Remark 2 | part 1. Contact interface conduction -- part 2. Nonarcing contacts -- part 3. The electric arc and switching device technology -- part 4. Arcing contact materials -- part 5. Sliding electrical contacts -- part 6. Contact data. |
520 ## - SUMMARY, ETC. | |
Summary, etc | Preface to the Second Edition Since the publication of the first edition of this book there have been some very costly system failures, which could have been prevented with a better knowledge of electrical contact phenomena. I will give two examples. The first is an electrical connector that supplied power to the Main Fuel Shut-off Valve in the F-16 fighter airplane. This connector used tin plated pins plugged into a gold plated socket. As will be briefly discussed in Chapters 3 and 4, the failure of this combination from fretting corrosion in the aircraft's vibration environment caused the fuel to stop flowing to the jet engines. Several F-16 crashes are attributed to this connector failure with a subsequent cost of over $100 M. In hindsight it is probable that this pin socket combination used extensively in the earlier F-111 airplane resulted in it cancellation. Failure of the connectors most probably resulted in this plane's performance changing from a terrain following aircraft to a terrain impacting one. The second example occurred in the Large Hadron Collider (LHC), which began its initial testing in September 2008. Soon after it began to operate, a connection to a 12 MVA transformer failed. This cut power to the main compressors that operated the cryogenic system for cooling the super conducting magnets in two sections. This failure caused extensive wiring damage that cost more than $20 M to repair and set back the initial operation of this expensive experimental system by about nine months-- |
700 1# - AUTHOR 2 | |
Author 2 | Slade, Paul G., |
856 40 - ELECTRONIC LOCATION AND ACCESS | |
Uniform Resource Identifier | https://www.taylorfrancis.com/books/9781315216829 |
942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
Koha item type | eBooks |
264 #1 - | |
-- | Boca Raton : |
-- | Taylor & Francis, |
-- | [2014] |
264 #4 - | |
-- | ©2014 |
336 ## - | |
-- | text |
-- | rdacontent |
337 ## - | |
-- | computer |
-- | rdamedia |
338 ## - | |
-- | online resource |
-- | rdacarrier |
520 ## - SUMMARY, ETC. | |
-- | Provided by publisher. |
650 #0 - SUBJECT ADDED ENTRY--SUBJECT 1 | |
-- | Electric contacts. |
No items available.